642HA-26
To operate power is applied continuously. A normally open initiate switch closure causes the solid state load switch to turn ON, energizing the load. This condition is maintained for as long as the initiate switch remains closed. Opening the initiate switch starts the preset delay period. At the end of the preset delay period the solid state switch turns OFF, de-energizing the load. A new cycle can be started via the initiate switch. Should the initiate switch re-close during timing the delay period will stop but the load will remain energized. When the initiate switch is opened the preset delay period is re-triggered. When the delay has reached time out, the load is de-energized and the timer is reset. This timer is commonly referred to as the "Cool Down Timer".

Control the timing of high power electric heaters, motors, lamps, transformers and other high current loads rated less than 15 amps (150 amps inrush). CMOS digital circuitry is combined with a high current solid state switch. P/C board and internal components are encapsulated in a flame retardant molded housing, fitted with quick connect wiring terminals. Available in all standard voltages and frequencies. Fixed or adjustable timing from 0.1 seconds to 24 hours.

  • High Current Timing Module
  • Cool Down Timer
  • Encapsulated
  • Rated to 15 Amp. / 1hp
  • Fully Solid State
  • CMOS Digital Circuitry
  • Life Expectancy - unlimited
  • Environment Protected
  • Tamper Proof
  • No False Operate
  • Switches 1800W at 120V, 3600W at 240V
  • Small Size - 2" x 2" x 15/16"
  • Lightweight - approximately 2.5 oz.
  • Rugged
  • Transient Protected to 6000V
  • Choice of 5, 10, 15 Amp. Load Rating

Specifications :

Series642H
Current5 A
Time Range (T)11.0 - 100 sec.
Voltage (AC)240 V
Repeat Accuracy± 0.25%
Reset Time150 ms
Operating Voltage Tolerance± 20 %
Min# Load Current80 mA
Max# Load Current15 A
Voltage Drop at 15 Amp#2.5 V
Leakage Current7 mA
Dielectric Strength1500 VRMS
Min# Insulation Resistance100 MΩ
Input Transient Protection6000 V
Power3600 W
Power11/6 hp
Operating Temperature-40 to +70 ºC
Storage Temperature-55 to +70 ºC
Relative Humidity (Operating)95 %
Linearity±5% Minimum from 10% to 90% of range
Timing Tolerance±9% + Tolerance of Rt Std., ±5% Special (Fixed)
Max# Allowable Bracket Temperature80 ºC
Isolation Output Switch to Bracket2500 VRMS
Max# Inrush10 Times Rated Load Current
Options (P)O - Customer Supplies Own Potentiometer or Resistor
A - Potentiometer Supplied as Loose Part
B - Externally Installed Resistor
C - Factory Fixed Internal
D - Trimmer Potentiometer Installed on Terminals
R - Internal Potentiometer with Thru Shaft
S - Internal Potentiometer with Screwdriver Slot